We offers a wide range in servicing process plants with our expertise, with our solution such as: consultations, field service, training and engineering
Excitation : DC Plused Display : 4 Lines LCD with backlight Line 1 : Date and Time Line 2 : 5 Digit flowrate 6 Digit energy value Error code Supply temperature Line 3 : 9 Digit totalizer for forward flow / reverse flow 9 Digit totalizer for heat / cold energy Error code content Return temperature Line 4 : Differential temperature Unit : L/s, L/min, L/hr, m3/s, m3/min, m3/hr, mL/hr, mL/min, mL/s, kW, MW, KJ/hr, MJ/hr, GJ/hr, Mcal/hr, Kcal/hr, Cal/hr, BTU/hr Measuring Range : Min. 0-0.15 m/s : Max. 0-15 m/s Accuracy : +/-0.2% of reading (Velocity≥0.5 m/s) : +/-0.001 m/s (Velocity<0.5 m/s) Repeatability : +/-0.05% of reading Current Output : 4-20 mA (Isolated) Load : Max. 600 Ω Pulse Output : Open collector Rating : 3-30 VDC, 50 mA Max. Pulse Rate : 1) Scaled pulse, (L/Pulse, Other) : 2) Frequency: 0-5000 Hz Communication : Bluetooth (Apply to Android System) RS485 (MODBUS Protocol) / BACnet
Keypad : 3 External keys for programming and display control Low Flow Cutoff : 0-9.9% Data Logger Function : 99 Date / time records for alarm Record Data : Date / time of power on/ off : 99 Years flow rate / energy / temperature / total flow / total energy Record data every one hour Damping : 0.1-99.9 s Self Diagnosis : The following error messages are displayed if failure occurs - Temperature failure - Temperature abnormal - Empty pipe - EEPROM abnormal Data Storage : Operation parameters and totalizer figures are stored by EEPROM for more than 10 years Cable Entry : Standard: M20 Option: 1/2" NPTF Protection Class : IP67 Ambient Temperature : -25-65 °C Material : Aluminum Alloy Temperature Input : PT1000, 2 wires Power Supply : 90-260 VAC, 50/60 Hz : 24 VDC +/-10% (Option) Power Consumption : 10-20 W (Dependent on sensor size) Weight : 4.5 kg Mounting : Bracket on 2" pipe
Four line LCD display Flow Rate / Energy / Totalizer / Temperature +/-0.2% value of reading Bi-direction flow measurement, and the display can rotate With hourly report, daily report, monthly report and yearly report query function 99 times / dates records for alarm 99 (total) times records for power on / off MODBUS, Bluetooth, BACnet protocol
More From Electromagnetic Flowmeter AMC3200E Series
The ACA50 Series signal calibrator can measure and output multiple signals including voltage, current, TC and thermal resistance. The adoption of high definition LCD screen and silicone keypad is convenient for operating. With long standby time, high precision and programmable output function. It's widely used in lab, PLC in industry site, process instrument, electronic valve and many other area's debugging.
The ACA60 Series is mainly designed for the calibration and maintenance of on-site industrial thermodynamic instrument and their system. Its complete and practical functions are easily accessible. With latest extensive digital-converted integrative circuit and large-screen display, it is supplied with functions of output, measurement, ITS-90 query and 24 VDC power supply, making it convenient for you to check and calibrate sensor, transmitter, displayed instruments, and control system on spot.
The AHT530 Series is a battery-powered, hand-held unit designed to configure, calibrate and troubleshoot to smart transmitter either remotely or nearby. AHT530 allows you to establish communication with a Hart field instrument over the existing 4-20 mA DC lines, covering the five process variables of flow, pressure, temperature and level, control valve etc.